Deltec Cozmo User Manual

Browse online or download User Manual for Unknown Deltec Cozmo. Deltec Cozmo User manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 137
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews

Summary of Contents

Page 1 - User Manual

User ManualDeltec Cozmo™ Insulin Pumpijg

Page 2

Important Information4PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»vider for health advice and Deltec, Inc. for information onservicing y

Page 3 - Table of Contents

Using the Pump - More Features90Personalizing the combination bolusThe programming shown on this page is only for makingthe Combination Bolus appear i

Page 4

Using the Pump - More Features91Delivering a combination bolus*If Correction Bolus is personal-ized to display in Meal Bolus,these screens appear.Cozm

Page 5 - Limited Warranty 123

Using the Pump - More Features92Stopping a combination bolusSelect deliveryto stopAll DeliveryTemporary RateCombination<Home Select>Cozmo<Sto

Page 6

Using the Pump - More Features93Temporary RateTemporary Rate allows you to temporarily raise or loweryour basal rate. This feature can be useful when

Page 7 - Important safety information

Using the Pump - More Features94Personalizing the temporary rate*Temporary rates which will appear in the menu are indicated by ;.**Preselected names

Page 8

Using the Pump - More Features95Using the temporary rate*This screen only appears if more than1 temporary rate is available.**If running a custom temp

Page 9

Using the Pump - More Features96Stopping a temporary rateCozmo<Stop Menu>Basal: Pattern 1Rate: 1.150 u/hrTemporaryRateRemainingTime: 0

Page 10 - Important Information

Using the Pump - More Features97Notes:________________________________________________________________________________________________________________

Page 11

Using the Pump - More Features98Notes:________________________________________________________________________________________________________________

Page 12 - Explanation of symbols

6 History & CommunicationsHistory Personalizing history Viewing history on the pumpCommunications My Treatment Assistant™ PC Communications Sy

Page 13 - Introduction

Important Information5PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»lems, remove the pump from use.☞The pump may be damaged if stored in e

Page 14

History & Communications99HistoryThe pump stores history in 2 ways:• by the delivery date; the pump stores delivery infor-mation for the previous

Page 15 - Glossary of Terms

History & Communications100Personalizing historyCozmo<Stop Menu>Basal: Pattern 1Rate: 1.150 u/hrBasal PatternLoadHistoryPump Settings<Ho

Page 16

History & Communications101Viewing history on the pumpOnce the reports are set to display in the menu, you canview them as part of History in the

Page 17

History & Communications102CommunicationsMy Treatment Assistant™ PC Communica-tions SystemMy Treatment Assistant™ is a Microsoft® Windows®-based p

Page 18

History & Communications103For specific information on installing My TreatmentAssistant™ on your computer and connecting yourpump to the computer,

Page 19 - Pediatric use

History & Communications104Notes:_________________________________________________________________________________________________________________

Page 20 - About this manual

7Technical InformationPump development standardsPump specificationsDescription of pump safety systemsInspecting the pumpWhat’s In This Section?Myriad

Page 21

Technical Information105Pump development standardsAAMI ID26: 1998 - Medical Electrical Equipment — Part 2:Particular requirements for the safety of in

Page 22 - Pump illustrations

Technical Information106ment 1 (1996; Amendment 2 (1996)CISPR14 (1993) - International Special Committee on RadioInterference, limits and methods of m

Page 23 - About the Pump

Technical Information107Bolus volume at blockage (occlusion) release:Approximately 4 unitsPower source:One AAA (IEC LR03) alkaline battery.☞Caution: D

Page 24

Important Information6PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»QAppears in pump display, with a message, to in-dicate a question you

Page 25

Technical Information108Blockage (occlusion) alert:18 psi ± 5psiBolus accuracy at set value of 0.1u:± 15% (measurement error ± 10%)Bolus accuracy at s

Page 26

Technical Information109Bolus increment: 0.05 units, 0.10 units, 0.50 units or1.00 unitsDefault: 0.10 unitsCarb ratio: 1u per 2grams to 1u per 50grams

Page 27 - Deltec accessories

Technical Information110mmol/L: 0.2 to 12 mmol/L in the following increments:• 0.2 to 1.5 mmol/L in increments of 0.05 mmol/L• 1.5 to 5 mmol/L in incr

Page 28

Technical Information111Basal PatternUser can edit (4 patterns, each with a possible 48 time/ratesegments) and start using basal patternsDelivery Spec

Page 29

Technical Information112Averages: User chooses number of days to average over:2 to 30 days in 1 day incrementsDefault: 7 daysPump Settings / Personali

Page 30 - Figure 7

Technical Information113Default: 08:00Display site reminder: Yes or NoDefault: NoMissed Meal Bolus Alerts: User can program up to 4;active alerts indi

Page 31 - Pump settings

Technical Information114Accuracy test resultsThe following graphs are designed to show flow accu-racy of the pump against given time periods. All grap

Page 32 - <Back Next>

Technical Information115Flow rate from startupTime interval: 15 minutesTotal time: 1485 minutes(24 hours, 45 minutes)Programmed rate: 0.05 units/hrFlo

Page 33

Technical Information116Safety features and fault detectionHardware safety featuresKey hardware safety features include a watchdog timercircuit, motor

Page 34

Technical Information117verifies this function during the watchdog test describedabove.Voltage detector circuitLow voltage detection is performed by p

Page 35

Important Information7PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»IntroductionCongratulations! You have selected the Deltec Cozmo™ Insu-

Page 36

Technical Information118ent from the written data, the software stops insulindelivery, initiates an alarm (either beep or vibrate) and asystem fault a

Page 37

Technical Information119Data used in calculationsCalculations on data used in some way to controldelivery of insulin are performed redundantly.The 2 c

Page 38

Index120IndexAAccess site 9, 41, 69Accessories 20belt clip 23cartridge 20infusion set 20IR adapter 20Accuracy test results 114Alarms 27, 55, 5

Page 39

Index121display in menu 86stopping 88FFactor 11Fill cannula 42Fill tubing 40Fluid path 9, 11GGastroparesis 11Glucose Reminder 2, 28, 35HHistor

Page 40

Index122RRegional Settings 24date format 24number format 24time format 24Restarting delivery 31SSafety features and faultdetection 116hardware

Page 41

Warranty123Limited WarrantyDeltec, Inc. (the “Manufacturer”) warrants to the Original end-userPurchaser that the Deltec Cozmo™ Insulin Pump (the “Pump

Page 42

Warranty124sible for any incidental, special or consequential damages of any kindor nature caused by or arising out of a defect or malfunction of theP

Page 43 - Loading a cartridge

PROOF (LR #3557), 2002-11-21 «5118-51A Cover, Cozmo User Manual»Deltec Cozmo, Deltec Cozmo logo design, The Freedom to Be You and My Treatment Assista

Page 44 - Using the Pump - Basics

Important Information8PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»Correction bolus• The correction bolus is used to lower high Blood Glu

Page 45

Important Information9PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»Glossary of TermsThe following is a list of terms that you should know

Page 46

Important Information10PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»CSII: Continuous Subcutaneous Insulin Infusion.DKA: See Diabetic Keto

Page 47

Important Information11PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»Extended bolus: A meal bolus delivered over an extended pe-riod of ti

Page 48

Important Information12PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»sweating, dizziness, cold or clammy skin, looking pale, tin-gling and

Page 49

Important Information13PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»Pediatric useUse of an insulin pump by pediatric patients should alwa

Page 50

iPROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»Congratulations! You have selected the Deltec Cozmo™Insulin Pump to help you in the treatme

Page 51

Important Information14PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»bohydrate, the user’s insulin to carbohydrate ratio is pro-grammed in

Page 52 - Meal Bolus

2 About the PumpPump IllustrationsDescription of features and buttonsDescription of pump display and menusDeltec AccessoriesBefore using the pump for

Page 53

About the Pump15Pump illustrationsFigure 1Figure 2Touch BolusbuttonCartridge capDown key(backlight)DisplayRight programkeyLeft programkeyBattery capIR

Page 54

About the Pump16Description of features and buttonsBattery cap (Figure 1)Holds the battery in place in the battery compartment.The pump uses one “AAA”

Page 55

About the Pump17FeaturesVibration alertIf you don’t want the pump to beep during alarms andalerts, you can program it to vibrate instead. Thisfeature

Page 56

About the Pump1810:10AM 1.12 u/hrkeypad to deactivate thescreensaver and return tothe home screen (pressingthe c key turns on thescreen backlight; the

Page 57 - Basal patterns

About the Pump19PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»Time and DateTime: 08 : 00 AMDate: 06 / 28 / 02<Done Next>nNext><

Page 58

About the Pump20Deltec accessoriesDeltec offers a variety of products for use with yourpump. A complete list of accessories with orderinginformation i

Page 59

About the Pump21Before using the pump for the firsttimeInserting a battery, programming the regional settings (ifrequired), and setting the time and d

Page 60

About the Pump22Self TestsDuring the self tests, the pump’s internal computerperforms tests on all the major hardware, computer, andelectronic systems

Page 61

iiPROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»Important InformationImportant safety information ...

Page 62

About the Pump23Attach the belt clip (Optional)Slide the pump into the belt clip withthe keypad facing out (see Figure 6).You can rotate the clip to w

Page 63

About the Pump24Pump settingsThe Pump Settings menu allows you to perform certainsetup functions, such as setting the time and date,setting up how the

Page 64

About the Pump25Regional SettingCozmo<Stop Menu>Basal: Pattern 1Rate: 1.150 u/hrPressMenuPressHomePressBackPressBackStart athome screenChoose P

Page 65 - Troubleshooting

About the Pump26Time and date☞Warning: The time and date must be set correctly,since basal patterns are time-based, and all of thehistory is stored ba

Page 66

About the Pump27Beep or VibrateChoose Beep or Vibrate* to signal alarms and alerts.Then, if using Beep, decide how loud the beep is. Lowis quietest an

Page 67

About the Pump28Personalizing alertsThe pump allows you to set up certain alarms and alertsthe way you prefer. These alerts/alarms are associatedwith

Page 68

About the Pump29should occur. For example, if you eat breakfast everyday between 7:00AM and 9:00AM, you could select6:45AM for the “Start” time, and 9

Page 69

About the Pump30Basal PatternLoadHistoryPump Settings<Home Select>Cozmo<Stop Menu>Basal: Pattern 1Rate: 1.150 u/hr<Back Select>Pump

Page 70

About the Pump31Stopping and restarting insulindeliveryYou can stop and restart insulin delivery from the homescreen.☞Warning: When stopping delivery,

Page 71

About the Pump32Program LockProgram Lock allows you to prevent anyone fromentering the menu without the proper code. You canstill troubleshoot most al

Page 72

iiiPROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»2. Attaching an infusion set and loading a filledcartridge into the pump ...

Page 73

About the Pump33Unlocking the menuYou can use an item in the menu without turning off theProgram Lock by following the procedure below. Toturn the Pro

Page 74 - Cleaning your pump

About the Pump34Notes:________________________________________________________________________________________________________________________________

Page 75 - Servicing your pump

3Using the Pump -BasicsLoading a cartridgeMeal bolus Standard bolus (units of insulin): setup Standard bolus: delivery Carbohydrate bolus: setup

Page 76

Using the Pump - Basics35Loading a cartridgeThe Load feature in the pump menu takes you througheach step needed to load a filled cartridge in the pump

Page 77

Using the Pump - Basics362. Attaching an infusion set and loading a filled car-tridge into the pump☞Warning: To avoid accidentally infusing insulin,di

Page 78

Using the Pump - Basics374. Open the pump’s Load menu and load cartridge.NOTE: You will not be able to load a cartridge thatcontains less than 20 unit

Page 79 - My DKA plan

Using the Pump - Basics38FastForwardPlease wait...FastForwardPlease wait...Not readyPushrod must moveforward.Remove cartridgethen press OKOKNo cartrid

Page 80 - Tips for sick days

Using the Pump - Basics395. Verify, by looking through thecartridge viewing window, that thecartridge is properly attached tothe pushrod. Fasten the c

Page 81 - My sick day plan

Using the Pump - Basics403. Fill the tubingFilling forces insulin from the cartridge into the infusionset tubing and pushes air out of the tubing. Fil

Page 82 - Your pump &:

Using the Pump - Basics414. Choosing an access site and inserting the accessdevice•Choose an access site. Anywhere you would normallyinject insulin ca

Page 83

ivPROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»Stopping an extended bolus ... 88Combination Bolus ..

Page 84

Using the Pump - Basics425. Fill cannulaFilling the cannula is an important step if you are usingan infusion set that has a separate access device (ne

Page 85

Using the Pump - Basics436. Set site change reminder and restart deliveryThe Site Change reminder screens appear here if turnedon in Pump Settings / P

Page 86

Using the Pump - Basics44Meal Bolus☞Warning: You should receive specific training onprogramming and delivering a meal bolus. Pleasecarefully read all

Page 87 - Correction Bolus

Using the Pump - Basics45Standard bolus (units of insulin): setup*This screen will only appear if any extended orcombination custom boluses were progr

Page 88 - <Cancel Deliver

Using the Pump - Basics46Standard bolus: deliveryCozmo<Stop Menu>Basal: Pattern 1Rate: 1.150 u/hrPressMenuPressSelectPress Select(Menu appears

Page 89 - Rate: 1.150 u/hr

Using the Pump - Basics47Carbohydrate bolus: setup*Prenamed custom carbohydrate boluses includeBreakfast, Lunch and Dinner. If any custom boluseswere

Page 90 - Home screen

Using the Pump - Basics48Carbohydrate bolus: deliveryCozmo<Stop Menu>Basal: Pattern 1Rate: 1.150 u/hrPressMenuPressSelectPress Select(Menu appe

Page 91 - Touch Bolus

Using the Pump - Basics49Basal patterns☞Warning: You should receive specific training onprogramming and using basal patterns. Pleasecarefully read all

Page 92 - Making Touch Bolus available

Using the Pump - Basics50Personalizing basal patternsCozmo<Stop Menu>Basal: Pattern 1Rate: 1.150 u/hrBasal PatternLoadHistoryPump Settings<H

Page 93 - Delivering a Touch Bolus

Using the Pump - Basics51Editing basal patterns☞Warning: It is vital to get the basal patternscorrect. If a basal rate is too high or too low, all you

Page 94 - Carbohydrate

1Important InformationImportant Safety Information Warnings and CautionsExplanation of symbolsIntroductionGlossary of termsPediatric useAbout this ma

Page 95

Using the Pump - Basics52Cozmo<Stop Menu>Basal: Pattern 1Rate: 1.150 u/hrPressMenuPressHomePressBackPressBackPressBackSelect Basal Pattern, the

Page 96

Using the Pump - Basics53Using basal patternsMany of the screens in the Basal Pattern menu can bepersonalized by programming the pump or by using MyTr

Page 97 - Delivering an extended bolus

Using the Pump - Basics54Notes:_______________________________________________________________________________________________________________________

Page 98 - Stopping an extended bolus

4 HelpAbout the alarms (beep/vibrate settings)Troubleshooting Alarms Alerts Other MessagesCleaning your pumpServicing your pumpTroubleshooting healt

Page 99

Help55PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»About the alarms (Beep/Vibratesettings)The pump can be set to “Beep” or “Vibrate” when

Page 100 - Units-Insulin

Help56PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»TroubleshootingAlarmsMessage in display What it means / Alarm How to make it stopBatte

Page 101 - Target: 150 mg/dl

Help57PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»Alarms - continuedMessage in display What it means / Alarm How to make it stopCartridg

Page 102 - Stopping a combination bolus

Help58PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»Alarms - continuedMessage in display What it means / Alarm How to make it stop*No key

Page 103 - Temporary Rate

Help59PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»Alerts - continuedMessage in display What it means / Alarm How to make it stopCheck bl

Page 104 - <Stop Menu>

Help60PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»Alerts - continuedMessage in display What it means / Alarm How to make it stopAlertBG

Page 105 - Using the temporary rate

Important Information1PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»Important safety informationWARNING: Read this entire manual before us

Page 106 - Stopping a temporary rate

Help61PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»Alerts - continuedMessage in display What it means / Alarm How to make it stopSite cha

Page 107

Help62PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»Other messagesMessage in display What it means / Alarm How to make it stopYour pump wa

Page 108

Help63PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»Messages - continuedMessage in display What it means / Alarm How to make it stopNotcom

Page 109 - What’s In This Section?

Help64PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»Messages - continuedMessage in display What it means / Alarm How to make it stopThis b

Page 110 - History & Communications

Help65PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»Cleaning your pumpRoutinely clean your pump to prevent buildup of dirt ordried fluids.

Page 111

Help66PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»Servicing your pumpShould your pump become damaged or broken, or if it isnot working p

Page 112

Help67PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»Troubleshooting health problemsLow blood glucose (hypoglycemia)Blood glucose lower tha

Page 113 - Communications

Help68PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»High blood glucose (hyperglycemia)Blood glucose level higher than target. Signs and sy

Page 114

Help69PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»Infusion Set and/or Access Site problems :Problem Corrective ActionPoor insulin absorp

Page 115

Help70PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»Diabetic Ketoacidosis (DKA)A serious condition that occurs when there is not enoughins

Page 116

Important Information2PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»☞Make sure that all caregivers, including for instanceschool personnel

Page 117 - Pump development standards

Help71PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»Tips for sick daysDuring illnesses like colds and flu, controlling your BGlevel may be

Page 118 - Specifications

Help72PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»Emergency suppliesAlways have emergency supplies on hand. The suppliesshould include:•

Page 119 - Technical Information

Help73PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»Personal pump removal guidelines______________________________________________________

Page 120 - Delivery specifications

Help74PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»minutes. Dry the pump off with a clean towel when youare finished. If swimming in salt

Page 121

Help75PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»Herbal supplements may also have an effect on your health.Never begin taking any herba

Page 122

Help76PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»Notes:________________________________________________________________________________

Page 123

5Using the Pump -More FeaturesProgramming and using these featuresCorrection bolus Personalizing the correction bolus Delivering a correction bolus

Page 124

Using the Pump - More Features77Programming and using thesefeatures☞Warning: Programming and using the features de-scribed in this chapter includes in

Page 125

Using the Pump - More Features78Once your duration of insulin action is correctly pro-grammed, when you use the correction bolus featureany still acti

Page 126 - Accuracy test results

Using the Pump - More Features79Personalizing the correction bolusCozmo<Stop Menu>Basal: Pattern 1Rate: 1.150 u/hrBasal PatternLoadHistoryPump

Page 127

Important Information3PROOF (LR #3557), 2002-11-25 «5118-51A Cozmo User Manual»of leakage can also mean opportunity for contamination lead-ing to inf

Page 128

Using the Pump - More Features80*Delivering a correction bolus with a meal bolus is discussed in the meal bolus(meal bolus, extended bolus and combina

Page 129 - Software safety features

Using the Pump - More Features81Touch BolusThe Touch Bolus feature allows you to bypass the menuwhen delivering a meal bolus. It is called the TouchBo

Page 130

Using the Pump - More Features82Making Touch Bolus availableThe programming shown on this page is only for making theTouch Bolus available. If you wan

Page 131 - Inspecting the pump

Using the Pump - More Features83Delivering a Touch BolusDelivering a Touch Bolus is performed by pressing theTouch Bolus button on the side of the pum

Page 132

Using the Pump - More Features844. When the number of beeps or vibrations is correct, pressand hold the Touch Bolus button until it beeps or vi-brates

Page 133

Using the Pump - More Features85Extended BolusSome meals release glucose into the bloodstream slowly.The extended bolus is designed to deliver the bol

Page 134

Using the Pump - More Features86Personalizing the extended bolusThe programming shown on this page is only for makingthe Extended Bolus appear in the

Page 135 - Exclusions:

Using the Pump - More Features87Delivering an extended bolus*If Correction Bolus is personal-ized to display in Meal Bolus,these screens appear.Cozmo&

Page 136 - Warranty Procedure

Using the Pump - More Features88Stopping an extended bolusSelect deliveryto stopAll DeliveryTem porary RateExtended<Home Select>Cozmo<Stop Me

Page 137 - Tel. +44 (0)1923 246434

Using the Pump - More Features89Combination BolusThe combination bolus combines the features of thestandard and extended bolus, which can be used when

Comments to this Manuals

No comments